商铺名称:深圳市鑫瑞阳科技发展有限公司
联系人:王先生(先生)
联系手机:
固定电话:
企业邮箱:1073187272@qq.com
联系地址:龙岗区盛平中路钟星大厦403
邮编:518172
联系我时,请说是在泵阀网上看到的,谢谢!
Features of default Modbus firmware | |
When you buy an I-7188E -MTCP controller, it already has the default Modbus firmware installed in Flash memory. The default firmware has the follows features:
|
CPU | |
CPU | 80188, 40MHz or compatible |
SRAM |
512K bytes |
Flash Memory | 512K bytes |
EEPROM | 2K Bytes |
NVRAM | 31 Bytes (battery backup, data valid up to 10 year) |
RTC (Real Time Clock) | Yes |
64-bit Hardware Serial Number | Yes |
Built-in Watchdog Timer | Yes |
Communication Interface | |
COM1 | RS-232 (TXD, RXD, RTS, CTS, GND) |
COM2 | RS-485 (D2+, D2-) |
Ethernet Port | 10BASE-T NE2000 compatible Ethernet Controller |
COM Port Formats | |
Data bit | 7, 8 |
Parity | Even, Odd, None |
Stop bit | 1 |
LED Display | |
5-Digit 7 Segment LED Display | Yes (for I-7188EXD-MTCP only) |
System LED Indicator | Yes |
Hardware Expansion | |
I/O expansion bus | Yes |
User defined I/O pins | 14 pins |
Dimensions | |
I-7188EX(D)-MTCP | 123mm x 72mm x 33mm |
Operating Environment | |
Operating Temperature | -25°C to +75°C |
Storage Temperature | -40°C to +80°C |
Power | |
Protection | Power reverse polarity protection |
Required Supply Voltage | +10 to +30V/DC (non-regulated) |
Power consumption |
2W for I-7188EX-MTCP 3W for I-7188EXD-MTCP |