详细介绍:
HI2300意大利哈纳HANNA HI2300台式Desktop电导率仪
HI2300是微电脑控制,电导/总固体溶解度/氯化钠台式测量仪。其独特的自动选择量程功能可根据测量样品自动识别和选择量程,无需更换探头。仪器采用手动或自动方式进行温度补偿,用户可自主选择温度系数值。也可关闭此功能进行实际的电导测量。仪器还设有稳定指示器,用以提醒用户何时记录测量结果。HI2300还含有GLP性能,存储的数据可通过RS232接口输入计算机。另外,用户需输入唯一的ID号码以鉴别仪器。
测量指标
|
电导率(EC)
|
总固体溶解度(TDS)
|
测量范围
(20℃或25℃温度补偿)
|
0.00 to 29.99μS/cm or 30.0 to 299.9μS/cm
300 to 2999μS/cm or 3.00 to 29.99mS/cm
30.0 to 200.0mS/cm
Up to 500.0mS/cm(不进行温度补偿时测量电导值)
|
0.00 to 14.99ppm or 15.0 to 149.9ppm
150 to 1499ppm or 1.50 to 14.99g/l
15.0 to 100.0g/l
Up to 400.0g/l(不进行温度补偿时测量TDS值)
|
解 析 度
|
0.01μS/cm(0.00 to 29.99μS/cm)
0.1μS/cm(30.0 to 299.9μS/cm)
1μS/cm(300 to 2999μS/cm)
0.01ms /cm(3.00 to 29.99ms/cm)
0.1mS/cm(30.0mS/cm以上)
|
0.01ppm(0.00 to 14.99ppm)
0.1ppm(15.0 to 149.9ppm)
1ppm(150 to 1499ppm)
0.01g/l(1.50 to 14.99g/l)
0.1g/l(15.0g/l以上)
|
精 确 度
|
±1%读数±(0.05μS/cm测量值)
|
±1%读数±(0.03ppm测量值)
|
校 正 点
|
内设六个校正点自动识别
|
电导校正同时TDS自动识别校正
|
转换因子
|
__
|
0.40 to 0.80(出厂默认值0.50)
|
温度补偿
|
自动或手动补偿0 to 60℃
|
自动或手动补偿0 to 60℃
|
温度补偿常数
|
0.00 to 6.00%/℃(出厂默认值1.90%/℃)
|
测量指标
|
盐度(NaCl)
|
温度(℃)
|
测量范围
|
0.0 to 400.0%
|
0.0 to 60℃
|
解 析 度
|
0.10%
|
0.1℃
|
精 度
|
±1%读数
|
±0.4℃
|
校 正 点
|
单点自动识别校正(推荐校正液HI7037)
|
2个温度校正点0℃和50℃(调整间隔±1℃)
|
配套电极
|
HI76310具有ATC功能四环高性能电导电极(电导常数K=1)
|
数据接口
|
RS232
|
配套电源
|
HI710006专用220V/12VDC电源
|
适用环境
|
0.0 to 50.0℃ 95%RH
|
尺寸/重量
|
240×182×74mm / 1200g
|
HI2300
|
测量主机、HI76310具有ATC四环电导电极、相关附件
|
HI2300P
|
测量主机、HI76310具有ATC四环电导电极、携带箱、相关附件
|
HI76310
|
ATC高性能四环电导电极
|
HI710006
|
专用220V/12VDC电源
|
HI76404
|
电极专用支架
|
HI920010
|
9-9数据连接线
|
HI92000
|
数据处理及升级专用软件包
|
HI2604
|
防潮、防水、防震专用携带箱
|
HI2300 is the microcomputer control, conductivity / TDS/ sodium chloride type measuring instrument. Theautomatic range switching function can identify andselect the range automatically according to themeasuring sample, no need to replace the probe. The instrument adopts manual or automatic way for temperature compensation, the user can choose thetemperature coefficient. Conductance measurementscan also turn off this feature for the actual. The instrument is also provided with a stable indicator, to remind the user when logging of measurement results.HI2300 also contains GLP performance, storage of data can be input into the computer via RS232 interface. In addition, the user needs to input the unique ID numberto identify instruments.
Technical index
Measurements of electrical conductivity (EC) total solidsolubility (TDS)
Measuring range
(20 ℃ or 25 ℃ temperature compensation) 0 to 29.99 S/cm or 30 to 299.9 μ S/c
300 to 2999 μ S/cm or 3 to 29.99mS/c
30 to 200.0mS/cm
Up to 500.0mS/cm (measured conductance valueswithout temperature compensation) 0 to 14.99ppm or 15 to 149.9ppm
150 to 1499ppm or 1.50 to 14.99g/l
15 to 100.0g/l
Up to 400.0g/l (TDS measurements withouttemperature compensation)
Analysis of 0.01 S/cm (0 to, 29.99 μ S/cm
0.1 μ S/cm (30 to, 299.9 μ S/c
1 μ S/cm (300 to, 2999 μ S/c
0.01ms /cm (3 to 29.99ms/cm)
0.1mS/cm (30.0mS/cm) 0.01ppm (0 to 14.99ppm)
0.1ppm (15 to 149.9ppm)
1ppm (150 to 1499ppm)
0.01g/l (1.50 to 14.99g/l)
0.1g/l (15.0g/l)
The accuracy of ± 1% readings ± (0.05 μ S/cmmeasurements) ± 1% readings ± (0.03ppm measurements)
The school is equipped with six point calibration pointcorrection and automatic recognition of TDS correctionautomatic recognition of conductance
Conversion factor of 0.80 by 0.40 to (default value0.50)
Temperature compensation and automatic or manualcompensation of 0 to at 60 ℃ manual or automaticcompensation of 0 to at 60 ℃
Temperature compensated constant of 0 to (6.00%/ ℃1.90%/ ℃ factory default value)
Measure salinity (NaCl) temperature (c)
The measurement range of 0 to 400% to 0 to at 60 ℃
Analysis of 0.10% 0.1 ℃
Accuracy of ± 0.4 ℃ ± 1% readings
The school is single point automatic recognitioncorrection (recommended correction fluid HI7037) 2 temperature correction at 0 ℃ and 50 ℃ (adjustment interval ± 1 ℃)
Auxiliary electrode HI76310 with ATC functions of high performance electrode (constant conductance K = 1)
Data interface of RS232
Auxiliary power supply
HI710006 special 220V/12VDC power
Application of 0 to at 50 ℃ 95%RH
Size / weight of 240 * 182 * 74mm / 1200g
Standard configuration
Measurement of HI2300, HI76310 with ATC host city of Victoria conductance electrode, related accessories
Measurement of HI2300P, HI76310 with ATC host city of Victoria conductance electrode, carrying case,related accessories
Optional accessories
HI76310 ATC high performance ring electrode
HI710006 special 220V/12VDC power
HI76404 electrode special support
HI920010 9-9 data cable
The HI92000 data processing and upgrade the software package
HI2604 moisture-proof, waterproof, shockproof special carrying box
上海-浙江-杭州-江苏-南京-无锡-苏州-北京-天津-重庆-沈阳-长春-吉林-哈尔滨-石家庄-唐山-西安-太原-济南-南京-杭州-成都-贵阳-昆明-西藏-拉萨-新疆-乌鲁木齐-内蒙古-呼和浩特-包头-银川-合肥-福州-南昌-武汉-长沙-南宁-海口-河北-秦皇岛-张家口-保定-廊坊-唐山-山东-青岛-淄博-烟台-威海-辽宁省-大连-鞍山-抚顺-丹东-黑龙江-大庆-齐齐哈尔-牡丹江-佳木斯-吉林省-延吉-四平-山西省-大同-长治-晋城-四川-攀枝花-自贡-宜宾-雅安-上海-浙江-杭州-厦门-宁波-昆山-嘉兴-湖州-常州-保定-锦州-湛江-辽宁-云南-陕西-青海-银川-北海-温州-常州-无锡-苏州-南京-镇江-扬州-南通-合肥-徐州-常熟
|