详细介绍:
6ES7321-1BL00-0AA0
6SN1123-1AB00-0CA1
1756-EN2T
A06B-6140-H015
6GT2801-2AB10
A06B-6079-H301
1769-L36ERM
特价现货供应
PLC:Allen-Bradley(AB)全系列,Schneider(施耐德)140,GE 通用电气 IC693 IC697 ,西门子 300 400 PLC
DCS:西屋 ovation,福克斯波罗 ,ABB 贝利 INFI90,TRICONEX ESD
伺服驱动/电机:FANUC,Rexroth,KUKA, ABB 机器人,Schneider LX17
板卡:摩托罗拉 Rexroth ABB KUKA Siemens GE MOORE Siemens
_________________________________________________
厦门航拓电气有限公司
xiamen hangtuo Electric Co., Ltd.
地 址:厦门市思明区仙岳路582号嘉怡园16楼 A单元
联系人:王先生
QQ:250421214
T:0592-5072097
P:18965131350
F:0592-5072083
www.xmhtdq.com
___________________________________________________
(诚信经营)(质量可靠)(进口正品)(顺丰空运)
Selecting the motor degree of protection
Effects Liquid/fluid
General
workshop
environment
Water;
General, cooling–lubricating medium
(95 % H2O; 5 % oil);
oil
Penetrating oil;
Petroleum;
aggressive cooling–lubricating
medium
Dry IP 64 – –
Environment where liquids and fluids are
present
– IP 641) IP 67
Mist – IP 65 IP 67
Spray – IP 65 IP 68
Jet – IP 67 IP 68
Splash;
brief immersion;
continuous flooding
– IP 67 IP 68
IP 1st code (0–6): Degree of protection against contact and the
ingress of foreign bodies
2nd code (0–8): Degree of protection against the ingress of water
(no protection against oil)
Operating temperature range: –15 °C to+40 °C.
All of the catalog data refer to an ambient temperature of 40 °C and assume
that the equipment is not mounted so that it is thermally insulated. The following
de–rating must be applied for ambient temperatures greater than 40 °C
to 45 °C 96%
to 50 °C 92%
to 55 °C 87%
to 60 °C 82%
Non–ventilated (9th position of the Order No.: A)
The power is dissipated by radiation and natural convection, which means that
the motor must be suitably mounted to guarantee adequate heat dissipation.
Servomotors can have high surface temperatures
(> 100 °C). When required, provide touch protection
Forced–ventilation (9th position of the Order No.: S)
Available for selected types (refer to Catalog)
for 1FT5 for shaft heights 71, 100 and 132,
for 1FT6 for shaft heights 80, 100 and 132
Forced ventilation is not available for 1FK6
It is not permissible that the hot discharged air is drawn in again.
1) For the version with holding brake and oil as cooling–lubricating medium: IP 67
30735866-001 30735866-501 Decoder Card - RCD
30735869-001 30735869-501 RCD backplane
30735871-003 RCD File/Backplane
30735873-001 30735873-501 Loop Module Card
30735876-001 C-JDP00 JDP00 Junction Panel
30735887-001 Printer Interface
30735892-001 30735892-501 Address Cable - RCD
30735974-003 Trend Memory - TDC 2000
30736220-001 Keyboard Interface
30750218-003 30750218-503 12K ROM/1K RAM - RCD
30750218-011 30750218-511 ROM/RAM: ST/DC - RCD
30750338-005 30750338-505 Hiway 2 Board
30750540-002 Op Station Power Supply
30750730-001 Diskette Interface
30750783-003 30750783-503 Diskette Bootstrap Board
30750990-001 Keyboard Interface Op Stn
30750990-002 Keyboard Interface
30751044-005 30751044-505 DHP Controller I ROM
30751044-006 30751044-506 DHP Controller II ROM
30751044-008 30751044-508 DHP Controller II ROM
30751044-010 30751044-510 DHP Controller II ROM
30751853-001 EDAC Error Detect & Correct Bd
30751856-001 128K MEM Op Station Mem Board 128K
30752551-001 DHP Backplane
30752588-001 CMOS RAM DHP 8K X 17 CMOS RAM
30752606-001 30752606-501 DHP Battery
30752766-001 30752766-501 DHP RS232C Transceiver
|