详细介绍: X003-7
2007/R7
SPECIFICATIONS
SCG353A043
SCG353A044
SCG353-052
SCG353-053
fl ow
coeffi cient
Kv
orifi ce
size
pipe
size
3/4
1
20
25
14
17
0,35
0,35
8,5
8,5
CM6-FT
CM6-FT
CM6-FI
CM6-FI
3/4
1
20
25
14
17
233
283
0,35
0,35
8,5
8,5
CM6-FT
CM6-FT
CM6-FI
CM6-FI
operating pressure
differential (bar)
~/=
air
max. (PS)
~ =
coil type
min.
233
283
(mm) (m3/h) (l/min)
(G*) - Threaded pipe connection
Ø - Compression fi tting pipe connection
catalogue
number
(1)
option
FPM
V
V
V
V
SCDUG353A043
SCDUG353A044
SCDUG353-052
SCDUG353-053
standard ATEX dust II3D
IN
FEATURES
• The diaphragm pulse valves are especially designed for dust collector service
applications, combining high fl ow, long life and extremely fast opening and
closing to produce reliable and economical operation
• The high fl ow, angle type bodies, springless construction, in combination with
the special diaphragm assemblies give the unique operating features
required for dust collector service applications
• The design with integral compression fi ttings will facilitate installation because
there is no need for threaded piping
• Built-in silencers guarantee noise free operation and avoid foreign particles
entering the valve
• The integral operators are provided with epoxy moulded F-class coils. Various
optional waterproof and explosionproof solenoids for use in potentially explosive
atmospheres (gas & dust) according to Directive ATEX 94/9/EC can be mounted
on the same basic valve (see pages 50 to 58)
• The components satisfy all relevant EC directives
CONSTRUCTION
Body Aluminium
Core tube Stainless steel
Core and plugnut Stainless steel
Core spring Stainless steel
Sealings & disc NBR (nitrile)
Diaphragm TPE (thermoplastic polyester elastomer)
Shading coil Copper
Coil insulation class F
Connector Spade plug (cable Ø 6 - 10 mm)
Connector specifi cation ISO 4400
Electrical safety IEC 335
GENERAL
Differential pressure (PS) 0,35 - 8,5 bar [1 bar = 100kPa]
Ambient temperature range -20 to +85°C
NC
IN
PULSE VALVES
single stage, integral pilot
threaded body or compression fi tting
3/4 to 1
inrush holding
nominal power ratings
(VA)
coil
type
(VA) (W) (W)
ambient
temperature
range
(°C)
protection
~ ~ =
CM6-FT
CM6-FI
34
-
6
-
-
14 / 20,8
15,6 -20 to +85 moulded IP65
(1) -
(1) Intermittent duty, Relative Duty Time is 10%. Max. on time is 1 min.
hot/cold
2/2
353
Series
ELECTRICAL CHARACTERISTICS
Standard voltages DC (=): 24V
(Other voltages and 60 Hz on request) AC (~): 24V - 115V - 230V / 50 Hz
fl uid temperature range (TS) piston/diaphragm
air -20 to +85 °C TPE
Availability, design and specifi cations are subject to change without notice. All rights reserved.
2007/R7
X003-8
SOLENOID VALVES SERIES 353
OPTIONS
IN
Fig. 1 Fig. 2
360 360
threaded type compression fi tting type
● Waterproof enclosure with embedded screw terminal coil according to protection class IP67, CEE 10
● Explosionproof solenoids for hazardous locations according to “ATEX” and national standards
● Explosionproof and watertight solenoids according to “NEMA” standards
● Compliance with “UL” standards
● Plug with visual indication and/or peak voltage suppression
● Electronic timer
● Valves can also be supplied with FPM (fl uorelastomer / viton) diaphragm and seal materials. Use the appropriate optional
suffi x letter for identifi cation
INSTALLATION
DIMENSIONS (mm), WEIGHT (kg)
● The valves can be mounted in any position without affecting operation
● Pipe connection identifi er is: G = G (ISO 228/1) or compression fi tting
● For compression fi tting types tightness is achieved by the compressed gasket on the blow tube
● The use of the rubber gaskets as sealing members will allow a slight misalignment in piping when using compression fi ttings
● Other pipe threads are available on request
● Installation/maintenance instructions are included with each valve
● Spare Parts Kit and replacement coils are available
(1) incl. coil and connector (C) construction type
catalogue number A B C D E F G H J K weight (1) (C)
SC(DU) G353A043
SC(DU) G353A044
SC(DU) G353-052
SC(DU) G353-053
75
75
75
75
45
45
45
45
27
27
27
27
51
51
88
88
89
89
125
125
75
75
75
75
39
39
39
39
92
92
92
92
113
113
175
175
130
130
195
195
0,70
0,65
0,85
0,90
Fig.1
Fig.1
Fig.2
Fig.2
X003-9
2007/R7
NC
IN
PULSE VALVES
dual stage, integral pilot
threaded body 1 1/2 to 3 or
compression fi tting Ø 1 1/2
FEATURES
• The diaphragm pulse valves are especially designed for dust collector service
applications, combining high fl ow, long life and extremely fast opening and
closing to produce reliable and economical operation
• The design with integral compression fi ttings will facilitate installation because
there is no need for threaded piping
• The high quality diaphragms are reinforced and wear resistant to guarantee a
long operating life, even under harsh conditions
• The integral operators are provided with epoxy moulded F-class coils. Various
optional waterproof and explosionproof solenoids for use in potentially explosive
atmospheres (gas & dust) according to Directive ATEX 94/9/EC can be mounted
on the same basic valve (see pages 50 to 58)
• The components satisfy all relevant EC directives
GENERAL
Differential pressure (PS) 0,35 - 8,5 bar [1 bar = 100kPa]
Ambient temperature range -20 to +85°C
CONSTRUCTION
Body Aluminium
Core tube Stainless steel
Core and plugnut Stainless steel
Springs Stainless steel
Sealings & disc NBR (nitrile)
Diaphragms CR (chloroprene)
Shading coil Copper
Coil insulation class F
Connector Spade plug (cable Ø 6 - 10 mm)
Connector specifi cation ISO 4400
Electrical safety IEC 335
inrush holding protection
nominal power ratings
(VA)
coil
type
(VA) (W) (W)
~ ~ =
CMXX-FT
CMXX-FF
55
-
23
-
10,5
-
-
14 / 19,7
(°C)
-20 to +85 moulded IP65
ambient
temperature
range
IN
hot/cold
2/2
353
Series
ELECTRICAL CHARACTERISTICS
Standard voltages DC (=): 24V
(Other voltages and 60 Hz on request) AC (~): 24V - 115V - 230V / 50 Hz
fl uid temperature range (TS) piston/diaphragm
air -20 to +85 °C CP
(2) Threaded pipe connection is external (male thread).
SPECIFICATIONS
SC G353A047 (1)
SC G353A050
SC G353A051
SC G353- 060 (2)
SC G353A065 (1)
fl ow
coeffi cient
Kv
orifi ce
size
pipe
size
1 1/2
2
2 1/2
3
52
66
66
75
44
77
92
170
0,35
0,35
0,35
1,0
8,5
8,5
8,5
6
CMXX-FT
CMXX-FT
CMXX-FT
CMXX-FT
CMXX-FF
CMXX-FF
CMXX-FF
CMXX-FT
1 1/2 52 44 733 0,35 8,5 CMXX-FT CMXX-FF
operating pressure
differential (bar)
~/=
air
max. (PS)
~ =
coil type
min.
733
1290
1540
2833
(mm) (m3/h) (l/min)
(G) - Threaded pipe connection
Ø - Compression fi tting pipe connection
catalogue
number
V
V
V
V
V
SCDU G353A047 (1)
SCDU G353A050
SCDU G353A051
SCDU G353- 060 (2)
SCDU G353A065 (1)
standard ATEX dust II3D
option
FPM
(1) Contains spring above the main diaphragm.
Availability, design and specifi cations are subject to change without notice. All rights reserved.
2007/R7
SOLENOID VALVES SERIES 353
OPTIONS
360°
360 360
Threaded type (Fig.1) Compression fi tting type (Fig.2)
External threaded type (Fig.3)
● Waterproof enclosure with embedded screw terminal coil according to protection class IP67, CEE 10
● Explosionproof solenoids for hazardous locations according to “ATEX” and national standards
● Explosionproof and watertight solenoids according to “NEMA” standards
● Hose connection executions (3" only)
● Compliance with “UL” standards
● Plug with visual indication and/or peak voltage suppression
● Electronic timer
● Valves can also be supplied with FPM (fl uorelastomer) diaphragms and seal materials. Use the appropriate suffi x
letter for identifi cation
INSTALLATION
● The valves can be mounted in any position without affecting operation
● Threaded pipe connection is: G (ISO 228/1) or compression fi tting
● For compression fi tting types tightness is achieved by the compressed gasket on the blow tube
● The use of the rubber gaskets as sealing members will allow a slight misalignment in piping
● Other pipe threads are available on request
● Installation/maintenance instructions are included with each valve
● Spare Parts Kit and replacement coils are available
DIMENSIONS (mm), WEIGHT (kg)
catalogue number A B C D E F G H J
SC(DU) G353A047
SC(DU) G353A050
SC(DU) G353A051
SC(DU) G353. 060
SC(DU) G353A065
1,40
2,90
2,60
4,10
1,75
K L weight (1)
80
80
80
80
80
50
50
50
50
50
30
30
30
30
30
71
95
95
143
117
130
168
168
240
177
136
165
165
192
136
45
45
45
45
45
G 3/8
G 3/4
G 3/4
G 1/2
G 3/8
131
165
165
165
131
161
210
210
258
225
178
227
227
275
242
Fig.1
Fig.1
Fig.1
Fig.3
Fig.2
(C)
(1) incl. coil and connector (C) construction type
X003-10
CONSTRUCTION
GENERAL
FEATURES
• The pulse diaphragm valves are especially designed for dust
collector service applications, combining high flow, long life
and extremely fast opening and closing to produce reliable
and economical operation
• The high quality diaphragms are wear resistant and guarantee
a long operating life, even under harsh conditions
• Easy installation directly into header tank
• Easy maintenance
• Normally Closed valve
• Internal Pilot Operated
PULSE VALVES
(Immersion Type - 3")
(1) Damage may occur when liquids solidify above the specified minimum temperature.
(2) Other voltages and 60 Hz available on request.
2/2
Series
353
NC
X003-AA-R0
fluid temperature range (1) diaphragm
air -20 to + 85°C Neoprene
Differential pressure 1 - 6 bar (1 bar = 100kPa)
Max. allowable pressure 6 bar
Ambient temperature range -20 to +85°C
Body Aluminium
Core tube Stainless steel
Core and plugnut Stainless steel
Springs Stainless steel
Sealing and disc NBR
Diaphragm Neoprene
Shading coil Copper
Coil insulation class F
Connector Spade plug (Pg 11P)
Connector specification ISO 4400
Electrical safety IEC 335
SPECIFICATIONS
ELECTRICAL CHARACTERISTICS
(mm) (m3/h) (l/min) ~ = ~ =
3" 75 mm 170 2833 1 6 - CMXX-FT - AC SCXE353.060 TPL: 17312
3" 75 mm 170 2833 1 - 6 - CMXX-FF DC SCXE353.060 TPL: 17313
pipe
size
min.
voltage
orifice
size catalog number
flow required
(kv)
coil type
operating pressure
differential (bar)
max.
Standard voltages (2) DC (=) 24V
AC (~) 24V - 115V - 230V / 50
inrush
(~)
hot/cold
(=)
(VA) (VA) (W) (W)
CMXX-FT 55 23 10.5 9 / 11.2 -20 to +85 °C moulded IP65
CMXX-FF - - - 14 / 19.7 -20 to +85 °C moulded IP65
protection
normal power ratings
holding
(~)
coil type
ambient
temperature
range (1)
(°C)
PULSE VALVES SERIES 353
X003-AA-R0
Weight - 2.8kg
INSTALLATION
· The valves can be mounted in any position without affecting operation
· Installation / maintenance instructions are included with each valve
· Spare Parts Kit and replacement coils are available
· Rubber gasket provided for mounting between valve and header tank
· 8 mounting bolts (M10) also provided
OPTIONS
· Waterproof enclosure with embedded screw terminal coil and Pg 13.5 cable gland to meet CEE 10 (IP67)
· Explosionproof and watertight enclosures according to “NEMA” standards
· Plug with visual indicator and / or with peak voltage suppression
· Electronic timer
DIMENSIONS (mm), WEIGHT (kg)
|